Abstract

We have developed an interdigital-H quadrupole (IHQ) linac for industrial applications. This linac was designed to accelerate particles with charge to mass ratio greater than 1/16 from 21.8 up to 145 keV/u. The particles are focused by an electric quadrupole field exited by fingertips on the drift tubes. This IHQ linac was installed at Tokyo Institute of Technology in 1997 and some tests such as low power tuning and vacuum tests were done. Then, proton acceleration tests ware performed in 1998, and the proton beam was successfully accelerated up to the designed energy. As a result of this experiment, the effective shunt impedance was determined to be 210 MΩ/m, the required RF power consumption was 93 W and the beam transmission rate was about 9%. In this paper, the results of the high power acceleration test with H + ion are described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.