Abstract

BackgroundWe performed comprehensive transmitral and pulmonary venous Doppler echocardiographic studies to devise a novel index of diastolic function. This is the first study to assess the utility of the acceleration rate (AR) of the E wave of mitral inflow as a primary diagnostic modality for assessing diastolic function.MethodsStudy group consisted of 84 patients (53 + 11 years) with left ventricle (LV) diastolic dysfunction and 34 healthy people (35 ± 9 years) as control group, who were referred for clinically indicated two-dimensional transthoracic echocardiogram (TTE) during 2012 and 2013 to Imam Hospital. Normal controls were defined as patients without clinical evidence of cardiac disease and had normal TTE. LV diastolic function was determined according to standardized protocol of American Society of Echocardiography (ASE). As our new parameter, AR of E wave of mitral inflow was also measured in all patients. It was represented by the slope of the line between onset of E wave and peak of it. Correlation between AR of E wave and LV diastolic function grade was measured using the Spearman correlation coefficient. Receiver operating characteristic (ROC) curve was used to determine the sensitivity and specificity of AR of E wave in diagnosing LV diastolic dysfunction in randomly selected two-thirds of population then its derived cutoff was evaluated in rest of the population. The institutional review board of the hospital approved the study protocol. All participants gave written informed consent. This investigation was in accordance with the Declaration of Helsinki.ResultsThe mean value of AR was 1010 ± 420 cm/s2 in patients whereas the mean value for the normal controls was 701 ± 210 cm/s2. There was a strong and graded relation between AR of E wave of mitral inflow and LV diastolic function grade (Spearman P ≤0.0001, rs =0.69). ROC curve analysis revealed that AR of E wave of mitral inflow =750 cm/s2 predicted moderate or severe LV diastolic dysfunction with 89 % sensitivity and 89 % specificity (area under curve [AUC] = 0.903, P <0.0001). Application of this cutoff on test group showed 96 % sensitivity and 77 % specificity with AUC = 0.932 and P <0.0001.ConclusionAR of E wave of mitral inflow could be used for assessment of diastolic function, especially moderate or severe diastolic dysfunction. However, before its clinical application, external validation should be considered.

Highlights

  • We performed comprehensive transmitral and pulmonary venous Doppler echocardiographic studies to devise a novel index of diastolic function

  • The assessment of left ventricular (LV) diastolic function and filling pressures is of paramount clinical importance to distinguish this syndrome from other diseases such as pulmonary disease resulting in dyspnea, to assess prognosis, and to identify underlying cardiac disease and its best treatment

  • Study group consisted of 84 patients with LV diastolic dysfunction and 34 healthy people as control group, who were referred for clinically indicated two-dimensional transthoracic echocardiogram (TTE) between 2012 January and 2013 May

Read more

Summary

Introduction

We performed comprehensive transmitral and pulmonary venous Doppler echocardiographic studies to devise a novel index of diastolic function. This is the first study to assess the utility of the acceleration rate (AR) of the E wave of mitral inflow as a primary diagnostic modality for assessing diastolic function. The assessment of left ventricular (LV) diastolic function and filling pressures is of paramount clinical importance to distinguish this syndrome from other diseases such as pulmonary disease resulting in dyspnea, to assess prognosis, and to identify underlying cardiac disease and its best treatment. Transmitral Doppler echocardiography has been routinely used to identify left ventricular diastolic dysfunction in patients [4, 5]. Problems related to the complexity of interpreting the transmitral flow profile still exist, and some of the better established clinical indices may need to be re-evaluated for their relevance

Methods
Findings
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.