Abstract
Facial fractures occur commonly as a result of blunt trauma from road traffic accidents, assaults, and sporting injuries. Orbital floor fractures form a significant proportion of these and when large enough, the defect often requires surgical reconstruction of the floor to prevent orbital content herniation. Here, we present a case of a 28-year-old gentleman, who sustained an orbital floor fracture from a soccer-related injury. The resulting floor defect was surgically repaired using an osteomesh that was hand-cut to size. He developed delayed enophthalmos and entrapment of the inferior rectus muscle due to early resorption of the osteomesh, requiring revision surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.