Abstract

A computerized analysis is outlined; it uses a lognormal distribution that is fitted to the observed data by the maximum likelihood method. A typical computer output illustrates the failure levels at operational temperatures. The statistical curve fitting technique aids the analysis of accelerated lifetest data. Failure estimates at junction temperatures, much lower than those under accelerated lifetest, are obtained by extrapolation. However, it is up to user whether such an extrapolation is justified. Due to the quantized nature of the data, an optimum exists for the time of device inspection, whereby statistical information is obtained at minimum testing expense. For example, inspecting the 250°C sample at 80 and 160 hours would be a waste of time since no failures should occur.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.