Abstract

Accelerated short-term leach tests in a laboratory are neccessary in order to estimate, with reasonable accuracy, the long-term leaching behavior of high-level waste glass. In the present study, static leach tests of an SRL-165 high-level waste glass were carried out in deionized water at two different glass-surface-area to solution-volume ratios (SA/V-ratio), namely 0.85 and 0.079 cm−1 at 90°C, and 0.85 cm−1 at 40°C. First, an equation was examined which related Si-concentrations with time, temperature and SA/V-ratio under the present static conditions. The parameter determined at 90°C, 0.85 cm−1 can be used to calculate the Si-concentration at 40°C, 0.85 cm−1. Second, at the low SA/V- ratio of 0.079 cm−1, the concentrations of Ca and Mg in the leachates peaked and then decreased a little. The equation used above does not explain the variation of the concentrations of Ca and Mg at a low SA/V-ratio. The precipitation of Ca and Mg onto the glass surface is probably caused by the adsorption efficiency of th...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.