Abstract

At high altitude, the external insulation safety of the electrified railway is threatened by low air pressure, pollution and other harsh factors. In order to inform the reasonable choice of external insulation for electrified railways at high altitude, this paper takes post insulator QBG-25/16 (2000) as the research object, simulates different air pressure and pollution situations, and studies AC flashover characteristics of pollution post insulator under low air pressure. The research shows the flashover voltage of post insulators decreases in a power function as the air pressure decreases as well as the pollution of the surface increases. The air pressure influence characteristic index of the flashover voltage of pollution post insulators is 0.456~0.610, and the pollution influence characteristic index of the flashover voltage of pollution post insulators is 0.377~0.432. In addition, the altitude correction of post insulators is also proposed. The results give a technical reference for insulation coordination of external insulation of electrified railway at high altitude.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.