Abstract
An investigation was conducted of the AC losses in coils with NbTi superconducting wires. The authors used the multiple-stacking procedure to prepare the wires, which varied in filament size from 10 mu m to 0.07 mu m. Three kinds of wires with 0.07- mu m filament were specially fabricated to estimate the proximity effect on AC losses. The distances between the filaments of these wires were 21 nm, 42 nm, and 70 nm, respectively. AC losses were measured for small coils at 60 Hz. The proximity effect was observed for the wires with 0.07- mu m filament when the distance was 21 nm. Conversely, when the distance was 42 nm, the loss decreased to the small value of 11 kW/m/sup 3/ at 0.5 T and 4.2 K. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.