Abstract

During the integrated commissioning of JT-60SA tokamak, the Toroidal Field (TF) magnet has experienced fast current discharges which have induced AC losses in its winding packs (WP) and in its casings. Using the thermo-hydraulic sensors network installed at the inlet and outlet of the TF coils, we have performed enthalpy balances to estimate the transient heat loads generated by AC losses. In parallel, we have modeled the hysteresis and coupling losses produced in the WP and the eddy currents losses produced in the casings by such events. We then assess and discuss the consistency between these experimental and first theoretical analyses from the energy balance point of view.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.