Abstract
In this paper, we propose a new AC loss measurement system for MgB <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> superconducting (SC) coils under rotating magnetic field. An AC loss measurement system using a Halbach array permanent magnet rotor and a torque meter is developed. A rotating magnetic field of 0.15 T peak at a maximum of 100 Hz is applied to the MgB <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> SC coils in the cryostat, and the AC loss is measured as the difference in mechanical input with and without the MgB <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> SC coils in the cryostat. The measurement results with cooling at 20 K and 25 K show that the AC loss at 60 Hz reached almost 7 W/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> . And the fact that the order of magnitude of the measured values is almost the same as that of the other groups shows that the proposed method can be used to measure AC loss of SC coils.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.