Abstract

AC losses of Nb/sub 3/Sn conductor samples with various void fractions for the ITER Central Solenoid Model Coil (CSMC) were measured by using calorimetric and magnetization techniques. The CSMC is designed to generate the magnetic field of 13 T at the operating current of 46 kA. The conductor consists of the multi-stage cable, having 1152 Nb/sub 3/Sn strands, and Incoloy 908 square jacket with circular hole. The strands are coated by chrome plating with 2 /spl mu/m layer. The last sub-cables are wrapped with Inconel tape, having high electric resistivity, to reduce the coupling current loss. The optimum void fraction for pulse coils is obtained from the relation between the coupling time constant and the void fraction. It is indicated that the sub-cable wrapping is very effective in limiting the coupling current between the sub-cables, as expected. The AC losses of the CS Insert were measured in various operating modes. From these obtained results, the validity of conductor design is demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.