Abstract
Statement of problemAngle-correcting options allow the use of screw-retained implant prostheses in situations where an implant has been placed with a facial inclination. However, manufacturers have different recommended torque values, and it is unclear whether the performance of these designs is equivalent to that of the traditional screw-retained crowns (SRCs) when subjected to cyclic loading forces. PurposeThe purpose of this in vitro study was to compare torque differences between conventional straight-line screw access and angulated access SRCs before and after simulated functional loading. Material and methodsFive groups consisting of 10 SRCs and implants were formed: Nobel Biocare zirconia crowns with 20-degree access channels (NB-20); Dynamic Abutment Solution zirconia crowns (DA-20) with 20-degree access channels; Core3dcentre angle correction zirconia crowns with 20-degree access channels (C3D-20); Nobel Biocare zirconia crowns with 0-degree access channels (NB-0); and gold alloy crowns cast to Nobel Biocare Gold-Adapt abutments (GA-0). Each specimen underwent thermocycling before cyclic loading. A preload torque based on the manufacturer’s recommendation was applied to each crown placed on an implant. Reverse torque measurements were obtained for each specimen before cyclic loading. Each implant-abutment assembly was then cyclic loaded at 0 to 100 N at 10 Hz for 1 million cycles. Reverse torque measurements were obtained after cyclic loading and the percentage difference calculated. ResultsNo significant percentage torque loss differences were observed between the 0-degree and 20-degree SRCs after cyclic loading. No significant differences were seen among the angulated access channel crowns. DA-20 and C3D-20 specimens had significantly higher torque loss compared with the NB-0 group. The C3D-20 group reported the largest percentage torque loss (34.5%) among the angulated access screw channel groups. The GA-0 group reported the largest percentage torque loss of all the groups (35.9%). No crown mobility or other complications were observed in any of the groups after cyclic loading. ConclusionsAngulated access channel crowns performed comparably with conventional straight-line screw access SRCs with regard to percentage torque values after cyclic loading. Angulated access channel crowns with lower manufacturer recommended torque values had higher percentage torque differences.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.