Abstract

Abstract Background Axillary lymph node (ALN) is the most common metastatic site of breast cancer (BC) and the status of ALN determines the staging, treatment and prognosis for BC patients. Traditional imaging techniques, including ultrasound (US), mammography, MRI, and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) were still unsatisfactory to evaluate the status of ALN non-invasively. Fibroblast activation protein (FAP) is highly expressed in cancer-associated fibroblasts and FAP inhibitor (FAPI) PET has been found quite promising in BC. Well-designed prospective large cohort study concerning the diagnostic performance and safety profile of FAPI PET/CT in detection of ALN metastasis of BC is still lacking. Furthermore, FAPI could be radio-labeled with different radio-nuclides including 68Ga and 18F, and there is yet no data concerning the 18F-labeled FAPI in BC. In this study, we investigated the accuracy of FAPI (both 68Ga-FAPI-04 and Al18F-FAPI-04) PET/CT in newly diagnosed BC patients for assessing ALN metastasis. We also compared the diagnostic performance of FAPI PET/CT with that of 18F-FDG PET/CT and US. Methods This prospective study was approved by the Peking Union Medical College Hospital Ethics Committee and was registered online at NIH ClinicalTrials.gov (NCT05574907, NCT05574920). The inclusion criteria were as follows: (1) age 18-80 years old; (2) newly diagnosed BC confirmed by biopsy or with BI-RADS category 4C or 5 lesions by US. The exclusion criteria were as follows: (1) pregnancy or lactation; (2) patients unwilling to undergo PET/CT scans. All patients received biopsy or surgery on breast lesion and ALN. Patients received FAPI and 18F-FDG PET/CT after enrollment. The safety profile of FAPI PET was monitored after injection using the Common Terminology Criteria for Adverse Events. Two experienced nuclear medicine physicians, who were blinded to the pathological diagnosis and other imaging results, assessed the PET/CT images. It was defined as visually positive if the radioactive uptake of the ALN was higher than that of the adjacent normal tissue. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each diagnostic test. The McNemar test was applied to compare the differences of sensitivity and specificity between FAPI PET/CT, 18F-FDG PET/CT, and US. All statistical tests were performed two-sided, and P< 0.05 was considered statistically significant. Results In total, 113 patients (27-79 years old, median age 66) were enrolled. 53 patients underwent 68Ga-FAPI-04 PET/CT, and the other 60 patients underwent Al18F-FAPI-04 PET/CT. All patients underwent 18F-FDG PET/CT and US. A total of 53/113 (46.9%) patients were finally diagnosed with ALN metastasis. The sensitivity, specificity, accuracy, PPV, and NPV were 90.6%, 90.0%, 90.3%, 88.9%, and 91.5% for FAPI PET/CT, 84.9%, 73.3%, 78.8%, 73.8%, and 84.6% for 18F-FDG PET/CT, 83.0%, 76.7%, 79.6%, 75.9%, and 83.6% for US, respectively (Table 1). The specificity of FAPI PET/CT was significantly higher than that of 18F-FDG PET/CT (P < 0.05) and US (P < 0.05). The sensitivity of FAPI PET/CT was higher than that of 18F-FDG PET/CT (P= 0.45) and US (P= 0.29). There was no significant difference of sensitivity and specificity between 18F-FDG PET/CT and US (P > 0.05). The sensitivity, specificity, accuracy, PPV, and NPV were 92.0%, 92.9%, 92.5%, 92.0%, and 92.9% for 68Ga-FAPI-04 PET/CT, and 89.3%, 87.5%, 88.3%, 86.2%, and 90.3% for Al18F-FAPI-04 PET/CT, respectively (Table 2). The 68Ga-FAPI-04 PET/CT and Al18F-FAPI-04 PET/CT procedures were well tolerated in all patients. The only adverse event was injection pain in 12/53 (22.6%) patients injected with 68Ga-FAPI-04, and 7/69 (10.1%) patients injected with Al18F-FAPI-04, which might relate to the ethanol in the imaging agent. Conclusion The FAPI PET/CT outperformed 18F-FDG PET/CT and US in the diagnosis of ALN metastasis among early breast cancer patients. The 68Ga-FAPI-04 and Al18F-FAPI-04 PET/CT have similar diagnostic performance. The FAPI PET/CT procedures were well tolerated in all patients. Table 1 Diagnostic performance of FAPI PET/CT, 18F-FDG PET/CT, and ultrasound in the diagnosis of ALN metastasis Table 2 Diagnostic performance of 68Ga-FAPI-04 and Al18F-FAPI-04 PET/CT in diagnosis of ALN metastasis Citation Format: Bo Pan, Zhixin Hao, Chao Ren, Lifan Zhang, Yidong Zhou, Qiang Sun, Li Huo. Accuracy and safety of fibroblast activation protein inhibitor (FAPI) PET/CT in diagnosis of axillary lymph node metastasis in early breast cancer patients: a prospective cohort study (PFB-01&02 study) [abstract]. In: Proceedings of the 2023 San Antonio Breast Cancer Symposium; 2023 Dec 5-9; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2024;84(9 Suppl):Abstract nr PS05-01.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call