Abstract

Background & Objectives: The LMA flexibleTM (LMA Flexible; Laryngeal Mask Co. Limited, Seychelles, Singapore) has been widely used for head and neck-related surgery and dental surgery. In this study, we compared two insertion techniques for LMA flexible. Materials & Methods: A one hundred and sixteen adult patients undergoing breast surgery were randomized to the two insertion techniques(standard technique vs 90° rotation insertion technique). The ease of insertion was assessed by the success rate at the first attempt. Heart rate and mean blood pressure were recorded 1 min before and 1 min after insertion. Postoperative complications were checked. Results: The first-attempt insertion success rate was 93% for the standard technique and 98.3% for the rotation technique (P =0.2) in Table I. There were no statistically significant differences in hemodynamic variables and complications between the two groups (Table II).Table II.: Insertion and Intraoperative variables.Conclusion: Our study suggests the 90° rotation insertion technique has not advantage compared with standard technique of digital manipulation in LMA flexible. Disclosure of Interest: None declared

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.