Abstract

Background: A ratio of early transmitral flow velocity (E) to early diastolic mitral annular velocity (E′) and a time interval between onsets of E and E′ (T E′-E ) has been proposed as a novel index to assess left ventricular (LV) filling pressure (FP). However, in patients with atrial fibrillation (AF), it is often difficult to obtain steady Doppler-derived values because of fluctuating R-R intervals. Recently, simultaneous recording of E and E′, and calculation of E/E′ and T E′-E n each cardiac cycle has been feasible with dual Doppler system (Hitachi EUB7500). Methods: Forty patients with AF were analyzed to evaluate the feasibility for estimating LVFP by simultaneous recording of E and E′. We measured E/E′ and T E′-E corrected by R-R interval (cT E′-E ) using a dual Doppler system, and LV pre-atrial pressure (pre-A) in 5 consecutive cardiac cycles. Results: E/E′ and cT E′-E had significant correlations with pre-A (E/E′: r=0.58, p<0.001; cT E′-E : r=0.78, p<0.001). The receiver-operating characteristic (ROC) analysis revealed that cut-off value of cT E′-E >34ms 0.5 had higher specificity and sensitivity to predicted pre-A>12mmHg than the value of E/E′ >10.1 (cT E′-E : sensitivity 94%, specificity 87%, E/E′: sensitivity 67%, specificity 43%). Conclusions: Even in patients with AF, the temporal analysis of E and E′ by the dual Doppler system was available for estimating elevated LVFP and provided an incremental value in addition to velocity analysis of pulsed and tissue Doppler indices.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call