Abstract

Abstract Introduction: The oncoReveal™ Dx Lung and Colon Cancer Assay (oRDx-LCCA) is an amplicon-based targeted next generation sequencing (NGS), in vitro diagnostic test that detects DNA variants across 22 genes, including single nucleotide variants (SNVs) and insertions and deletions (INDELs) in KRAS and EGFR, from DNA isolated from formalin-fixed paraffin-embedded (FFPE) non-small cell lung cancer (NSCLC) and colorectal cancer (CRC) tumor tissue specimens. It is approved by the FDA as a companion diagnostic (CDx) for identifying approved therapeutic treatments for KRAS G12/G13 wild-type variants in CRC, and EGFR L858R variants and exon 19 in-frame deletions for NSCLC. oRDx-LCCA can detect non-CDx variants such as EGFR T790M, G719X and exon 20 insertions in NSCLC and KRAS Q61X and A146T and BRAF V600E in CRC. Variants are detected using Pillar Biosciences’ proprietary PiVAT® (Pillar Variant Analysis Toolkit) software. Methods: DNA input range was evaluated at 6 concentrations between 5 - 160ng in duplicate using DNA extracted from 15 clinical FFPE samples containing SNVs and INDELs from representative targeted mutations. Accuracy was determined by comparing detected variants with an externally validated comparator (CompO) across 208 samples (84 CRC, 124 NSCLC). Limit of detection (LoD) was determined by serial dilution of KRAS, EGFR, or BRAF positive FFPE samples in normal DNA to detect variant allele frequency (VAF) between 1 - 10%. Reproducibility tests were performed across 3 sites, 9 runs, 6 operators, 3 reagent lots and 3 thermocyclers, resulting in a total of 360 libraries. The non-inferiority (NI) statistical test was used to compare the oRDx-LCCA with an FDA approved CDx assay for EGFR exon 19 deletions and L858R mutations (CompQ) and for KRAS G12/G13 mutations (CompC). Synthetic FASTQ files were created at VAFs above and below the variant detection threshold for CDx mutations and used to validate quality control parameters, mean coverage, and on-target rate. Results: Effective DNA input range was determined to be between 10 - 80ng. LoD’s for KRAS G12/G13, EGFR L858 and exon 19 deletion, and BRAF V600E were established at < 4%. Positive percent agreement (PPA) and negative percent agreement (NPA) between oRDx-LCCA and CompO were > 99% each. Across all variables tested for reproducibility, the average percent positive agreement (APA) and average percent negative agreement (ANA) were each > 95%. NI margin was calculated to be < 10% between oRDx-LCCA and CompQ across all NSCLC samples and between oRDx-LCCA and CompC across all CRC samples. A total of 61 synthetic FASTQ datasets were created to validate the functionality and accuracy of PiVAT including VAF thresholds for 126 SNV and INDEL CDx variants. Conclusion: oRDx-LCCA is a highly accurate FDA approved IVD assay and PiVAT is a powerful FDA approved software tool for the detection of clinically relevant KRAS variants in CRC and EGFR variants in NSCLC and determination of approved therapy. Citation Format: Gloria Chan Johnson, Jordan Aldersley, Nicholas Lodato, Jamie Lim, Ian Flockhart, Mark Urbin, Yue Ke, Sean Polvino, Martin Zillmann, Gang Song, Zhaohui Wang. Validation of FDA approved oncoReveal Dx lung and colon cancer assay (oRDx-LCCA) [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2022; 2022 Apr 8-13. Philadelphia (PA): AACR; Cancer Res 2022;82(12_Suppl):Abstract nr 5795.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call