Abstract

Abstract Objectives: Although even conventional nuclear medicine tests could successfully detect tumor masses in vivo, they did not always visualize heterogeneous interiors of tumor masses. The clear visualization of intratumoral heterogeneity in vivo will give us additional information about the choice of cancer therapy. Recently developed single photon emission computed tomography (SPECT) scanners dedicated for small animal imaging show excellent spatial resolution (< 1 mm) and they are expected to visualize intratumoral heterogeneity in vivo even for mouse tumors. But, little studies have revealed the requisites for this purpose. In this study, we considered the conditions to image intratumoral heterogeneity in vivo. Materials and Methods: A small animal SPECT/CT scanner with four detectors equipped with 9-pinhole collimators (1.0 mm or 1.4 mm of pinholes, Bioscan, Washington, D.C.) was used. First, phantom experiments with 111In of similar radioactivity that is commonly used in mouse imaging studies were performed to evaluate the optimal conditions to obtain best spatial resolution and concentration linearity. Then, mouse tumors were imaged. 111In-labeled liposomes with high specific activity and high concentration were injected to Sarcoma180 bearing ddY mice. In vivo SPECT images and ex vivo autoradiograms were compared and the radioactivity distribution in tumors and other tissues was measured. Results: In phantom experiments with 111In, the best spatial resolution under the current experimental conditions simulating in vivo small animal imaging was 1.1 mm (1.4 mmϕ, 5 MBq/mL, 120 min of total acquisition), although they greatly depended on total acquisition counts or total radioactivity. The good linearity between the concentration and SPECT values was obtained under the condition of 0.5-1.5 MBq/mL. 111In-labeled liposomes (15-20 MBq/mouse) were strongly accumulated in the tumor (1-2 MBq/g, 10-15% of injected dose/g), predominantly in the marginal regions of tumors. And, SPECT clearly visualized this heterogeneous intratumoral localization in vivo with good spatial resolution with the acquisition time of 60 min at 24h after the injection. The threshold to clearly visualize the tumor heterogeneity was about 0.5 MBq/g. Ex vivo autoradiograms of excised tumors demonstrated that the small animal SPECT scanner could successfully image the heterogeneous intratumoral accumulation of liposomes. Conclusion: The SPECT/CT scanner dedicated for small animal imaging successfully visualized the tumor heterogeneity in vivo using radioactive probes with rather high specific radioactivity and high concentration. Citation Format: {Authors}. {Abstract title} [abstract]. In: Proceedings of the 101st Annual Meeting of the American Association for Cancer Research; 2010 Apr 17-21; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2010;70(8 Suppl):Abstract nr 4325.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.