Abstract
Abstract a) The advent of precision oncology has led a shift towards biomarker-driven clinical trial designs and molecular profiling of individual patients. Identification of patients with the target biomarker profile may be useful in guiding patient selection as an enrichment strategy for clinical trials. Targeted multiple reaction monitoring mass spectrometry (MRM-MS) analysis for multiplexed quantitation of biomarker proteins in FFPE tissue provides direct, more accurate and precise quantification over current ‘gold standard' immunohistochemistry (IHC) methods. However, MRM-MS has not yet been broadly applied to clinical trials. In this study, we demonstrate the systematic development, optimization and analytical validation of quantitative, multiplexed MRM-MS assays for robust biomarker quantification in clinical FFPE tissues, including sample analysis under GCLP. Results from an MRM panel targeting 8 clinically relevant biomarker proteins will also be shown, including the measured HER2 levels in FFPE breast tumors classified by IHC as 0, 1+, 2+ or 3+. b) MRM-MS biomarker panels were developed and optimized for multiplexed quantitation of ≤12 proteins, in which unique peptides derived from each target protein were monitored as a surrogate measure of protein levels. Tumor regions from FFPE tissue sections were dissected using laser capture or macrodissection, solubilized, digested with trypsin to generate peptides for analysis, spiked with fixed levels of stable isotope labeled (SIL) peptide standards, and analyzed by MRM-MS. Analytical validation was performed per NCI CPTAC guidelines, including response curves, assay repeatability, selectivity, stability, and reproducibility of endogenous detection. Clinical performance was assessed using commercially sourced FFPE-tumor tissues, including a cohort of breast tumor tissues with a wide range of HER2 expression. c) Assay performance results were protein/peptide dependent, with sensitivity in the low pg/μg total protein range. For HER2, assay linearity was demonstrated over 2.5 to 3 orders of magnitude, with a precision and accuracy of <15% over 3 independent runs. In sample analysis, the MRM-MS was sufficiently sensitive to detect HER2 in 1 μg total protein from FFPE breast tumor classified by IHC as negative (0). d) GCLP-compliant quantitative multiplexed large-scale clinical analysis of protein biomarkers by MRM-MS in FFPE tissue is feasible and enables precise and accurate quantitation of proteins when IHC methods are unsuitable or unavailable. Data can be used for patient stratification, optimization of treatment outcomes, drug resistance prediction, and to support clinical development of novel therapies. Citation Format: Maxim Isabelle, Michael Schirm, Gwenael Pottiez, Rudolf Guilbaud, Lorella Di Donato. Clinical proteomics for patient stratification - a GCLP quantitative mass spectrometry workflow for multiplexed measurement of protein biomarkers in FFPE tissues [abstract]. In: Proceedings of the Annual Meeting of the American Association for Cancer Research 2020; 2020 Apr 27-28 and Jun 22-24. Philadelphia (PA): AACR; Cancer Res 2020;80(16 Suppl):Abstract nr 4163.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.