Abstract

Abstract Increased use of next-generation sequencing has led to the discovery of many variants of uncertain significance, which are not clearly categorized as pathogenic or benign. In silico tools were developed to help classify these variants. However, the outcomes are different due to variations between the prediction algorithms. The purpose of this study is to evaluate the performance of 6 widely-used in silico tools in identifying drug-actionable gene variants as pathogenic or benign in 9 solid cancers. We selected drug-actionable genes according to NCCN guidelines in 9 common solid cancers: breast, ovarian, colorectal, melanoma of skin, thyroid, bladder, pancreatic, prostate, and biliary. Although lung cancer is also a common cancer, given that it has many genetic markers that are already widely studied, we focused on other solid cancer types for our analysis. From these genes, we collected information on 642 total missense variants (pathogenic = 435, benign = 217). Each variant was determined to be benign or pathogenic based on assertions from three databases: ClinVar, OncoKB, and My Cancer Genome. We selected variants with at least 2 or more concordant databases and excluded variants with conflicting classifications. We evaluated the performance of the in silico tools (Polyphen-2, Align-GVGD, MutationTaster2021 (MT2021), CADD, CONDEL, and REVEL) using overall accuracy, sensitivity, specificity, Matthews correlation coefficient (MCC), and likelihood ratio (LR+, LR-). All of the in silico tools demonstrated high sensitivity (0.78 - 1.00). However, excluding MT2021, all tools demonstrated low specificity (MT2021: 0.85, Other: 0.26 - 0.59). Overall accuracy ranged from moderate to high values across the tools (0.62 - 0.94). Besides MT2021, MCCs were found to be especially low (MT2021: 0.87, Other: 0.08 - 0.48) as well as LR+ (MT2021: 6.65, Other: 1.09 - 1.88). Most of the tools had high values of LR- (0.14 - 0.74) but MT2021 and CADD showed low LR- (0.06, 0.00). MT2021 showed the highest level of performance with the highest specificity (0.85), overall accuracy (0.94), MCC (0.87), and LR+ (6.65), a high sensitivity (0.99), and a low LR- (0.06). Conversely, Align-GVGD had the lowest level of performance with the lowest specificity (0.26), overall accuracy (0.62), MCC (0.08), and LR+ (1.09), and the highest LR- (0.74). The results show that even widely-used tools have very different performance and limitations as diagnostic tools. The high sensitivity group of in silico tools (CADD: 1.00, MT2021: 0.99, REVEL: 0.93) could be used to rule out the pathogenic variants. MT2021 with a relatively high specificity (0.85) and LR+ (6.65) could be considered as an additional test to rule in the pathogenic variants. However, given the different limitations associated with each in silico tool, clinicians should be cautious in using them to aid their clinical decisions when evaluating actionable targets. Citation Format: Chiwoo Song, Emma Yu, Ilene Hong, Grace Lee, Alice D. Lee, William Cheng, Eugene Kim, Young Kwang Chae. Evaluation of in silico tools for variant classification in missense variants of solid cancer with actionable genetic targets [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2022; 2022 Apr 8-13. Philadelphia (PA): AACR; Cancer Res 2022;82(12_Suppl):Abstract nr 2722.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call