Abstract
Endothelial progenitor cells (EPCs) are circulating undifferentiated pluripotent cells capable of reconstituting endothelium in vivo and diminishing lesion formation following arterial injury. We tested the hypothesis that treatment with a specific soluble GSK 3β-inhibitor (GSK3βi) would improve the in vitro yield and function of EPCs from patients with coronary artery disease (CAD) and augment their in vivo potential to improve arterial repair after injury and stent implantation. In vitro treatment with GSK3βi at 1× (IC50) and 2× (IC50) increased the number of cells that dual labelled for acLDL and UEA-1 lectin on day 7 (13.4±3.2 vs. 39.9±5.3 vs. 43.8±10.1; p < 0.05). Furthermore, GSK3βi significantly augmented CAD-EPC survival to levels equal to those of healthy controls, increased VEGF secretion (7.1±1.6 vs 30.0±8.9, p<0.05) and resulted in a 4× increase in adhesion (p<0.05). Using Q-PCR, mRNA copy numbers for VLA-1,2,3,4 and 5 were assayed; however, only VLA-4 levels increased (4×, p<0.01). Use of a VLA-4 specific blocking antibody confirmed that the improved EPC adhesion was specifically mediated by VLA-4. Finally, the effects of GSK 3β inhibition were tested in two in vivo models of arterial injury. CD-1 athymic nude mice underwent femoral artery wire injury and injection of CAD-EPCs that were either GSK3βi treated, untreated, or injection with vehicle alone. GSK3βi treated EPCs improved the ability of xenotransplanted cells to inhibit lesion formation when compared to untreated and vehicle arteries respectively (intima/media ratios: 0.3±0.1 vs. 5.3±1.2 vs 11.2±2.7 μm, p<0.01). GSK3βi coated stents were inserted into rabbit carotid arteries. Fourteen days after stent deployment, GSK3βi stents resulted in a 44% increase in re-endothelialization (assessed by scanning electron microscopy and compared to vehicle coated stents; p<0.01) and a 16% trend towards a reduction in neointima formation (p<0.09). In summary, our data demonstrates that GSK3βi improves EPC function in vitro and ameliorates arterial repair following injury and stent insertion in vivo .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.