Abstract

Introduction: The most common complication of alcohol septal ablation (ASA) is periprocedural high grade AV block (HGAVB). No long-term follow-up of cardiovascular implantable electronic device (CIED) utilization after ASA has been reported. Hypothesis: Pacemaker dependence on long-term follow up can be predicted by ECG or procedural characteristics. Methods: We analyzed all patients with hypertrophic cardiomyopathy who underwent ASA from December 1998 to December 2019 at our institution and received their first CIED within 30 days after ASA for HGAVB. All available follow-up interrogations were reviewed. CIED dependence was defined as ventricular pacing of ≥5%. CIED programming was determined by the patients’ cardiologists' discretion. Results: A total of 103 patients with hypertrophic cardiomyopathy underwent ASA. The average follow up duration was 10.1 years. Within 30 days after ASA, a total 25 patients received a CIED for HGAVB. On long term follow-up 16 patients (64%) were found to be CIED-dependent. Baseline characteristics, including pre and post-ASA ECG, were not significantly different between dependent and non-dependent patients (Table). The only predictor for CIED dependence was >1 ml of alcohol injected during ASA (OR 6.0, p<0.046). Conclusions: CIED implantation after ASA is common. Almost two thirds of patients who received CIED for postprocedural HGAVB were CIED-dependent on long term follow up. CIED dependence can be predicted by amount of injected alcohol >1 ml during ASA.