Abstract
Purpose: The LUNA Aneurysm Embolization System (AES) is a new self-expanding ovoid device that serves as an intra saccular flow diverter as well as a scaffold for endothelization across the neck. The objective of this prospective clinical study aiming to include a total of 63 patients was to evaluate the ability of the AES to occlude intracranial aneurysms while maintaining patency of the parent artery. Materials and Methods: Immediate post-implantation occlusion grade (complete (complete obliteration of the aneurysm including the neck), near-complete (persistence of any portion of the original defect of the arterial wall), or incomplete (any opacification of the sac) compared to baseline), and parent vessel compromise were evaluated. Patients underwent neurological testing with the Modified Rankin Scale and the National Institute of Health Stroke Scale (NIHSS) at baseline and time of discharge. Follow-up included clinical assessment at one, 3, 6, 9 and 12 months, and angiographic follow-up at 6 and 12 months. Results: 50 patients (9 men) with 47 unruptured and 4 ruptured saccular aneurysms (38 bifurcation, 13 sidewall, sizes from 3.9 to 10.1 mm) were enrolled to date in the study. In all but 2 aneurysms (2 failed procedure converted in coiling) 1 LUNA AES was deployed per aneurysm. In 5 cases, the LUNA AES placement was carried out with balloon microcatheter assistance. In one case, the LUNA AES placement was carried out with a stent. Clinical follow up was uneventful in all but 2 patients (one sustained SAH from a contralateral MCA aneurysm, one had GI bleeding). Immediate complete/near complete occlusion was obtained in 26.5% (13/49). At 6 month follow-up, complete/near complete occlusion was obtained in 70.8% (34/48). There was no parent artery occlusion. None of the treated aneurysm (re)bled during follow-up. 4 aneurysms treated with the LUNA needed retreatment (2 incomplete deployment of the LUNA into the sac, 2 angiographic recurrences). Conclusion: Preliminary results demonstrate good safety profile. Angiographic follow up are promising.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.