Abstract
The amount of cyclosporin A in an oil-in-water emulsion drug delivery system was determined by HPLC. The direct extraction and analysis of an intact emulsion were compared to the analysis of a cracked emulsion and an olive oil solution of the drug. The intra- and interday variability for the intact emulsion was less than 10% from 35 to 150 micrograms/ml, with recovery of 94%. Comparison of the assay results obtained with the emulsion and the olive oil solution gave a highly correlated regression line with a small intercept and a slope close to unity. Thus, the direct extraction and HPLC analysis of drugs in emulsions may be a viable approach to evaluate drug content.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.