Abstract
Systematic investigations on the effect of static disorder on p-wave superfluid 3He have been made possible by utilizing the unique structure of high porosity silica aerogel. For the past 10 years, a burst of experimental efforts revealed that three distinct superfluid phases exists. We have performed longitudinal ultrasound (9.5 MHz) attenuation measurements in the B-phase of the superfluid 3He in 98% aerogel. The absolute attenuation was determined by direct propagation of sound pulses through the medium in a wide range of temperatures, down to 200 μK, for sample pressures of 10 and 29 bars. Our results provide direct information on the zero-energy density of states of the superfluid phase in aerogel originating from impurity scattering.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.