Abstract
Xe is an ideal anesthetic gas, but it has not been widely used in practice due to its high cost and low output. Closed-circuit Xe recovery and recycling is an economically viable method to ensure adequate supply in medical use. Herein, we design an innovative way to recover Xe by using a stable fluorinated metal-organic framework (MOF) NbOFFIVE-1-Ni to eliminate CO2 from moist exhaled anesthetic gases. Unlike other Xe recovery MOFs with low Xe/CO2 selectivity (less than 10), NbOFFIVE-1-Ni could achieve absolute molecular sieve separation of CO2 /Xe with excellent CO2 selectivity (825). Mixed-gas breakthrough experiments assert the potential of NbOFFIVE-1-Ni as a molecular sieve adsorbent for the effective and energy-efficient removal of carbon dioxide with 99.16 % Xe recovery. Absolute CO2 /Xe separation in NbOFFIVE-1-Ni makes closed-circuit Xe recovery and recycling can be easily realized, demonstrating the potential of NbOFFIVE-1-Ni for important anesthetic gas regeneration under ambient conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.