Abstract

This article describes an "absolute" calibration of TOPEX/POSEIDON (T/P) altimeter bias using UK tide gauges equipped with Global Positioning System (GPS) receivers. The method is an extension of earlier work using the Newhaven tide gauge in the English Channel. However, the present analysis extends the research to a number of gauges around the UK and incorporates several improvements. The time-averaged TOPEX and POSEIDON biases are obtained with a precision of approximately 2 and 3 cm, respectively. The research complements work on bias determination by other groups in the T/P Science Working Team and can, in principle, be applied at other locations for which precise, local geoid-differences are available. The relatively sparse POSEIDON data set has been used as a test of our ability to perform an absolute calibration of upcoming Jason-1 altimetry as soon as possible after launch.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.