Abstract

In preclinical studies, monoclonal antibodies (mAbs) are traditionally assayed by ligand-binding-assays. Recently, quantitative liquid chromatography mass spectrometry (MS)-based assays have emerged which circumvent a number of challenges. These assays may also be multiplex, making them potentially compatible with pharmacokinetic assays for combined antibody therapies. We combined a quantitative MS-based approach with the protein standard for absolute quantification (PSAQ™) strategy to simultaneously quantify three mAb variants presenting minor sequence differences. Stable isotopically labeled mAbs were produced and used as quantification standards. Titration curves were performed to assess the analytical performances of the method. LC-MS/MS and ELISA data were cross-compared. The approach presented provides similar accuracy and precision than ELISA, while being multiplex and faster to develop. It has applications at all stages of the pharmaceutical development.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.