Abstract

The failure and collapse of edge beam were caused by the synergy of the following factors: the improper design of beams in the axes A and E, particularly with reference to shearing and torsion, the improper design of the column in the axes A and 1, the improper design of laps in the reinforcement, the performance of laps in the reinforcement which did not match the design, and the inaccurate embedment of the beam in concrete. And lower class of concrete should be regarded as the secondary cause.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.