Abstract
ABO-mismatched plasma and platelet (PLT) transfusion have been associated with worse outcomes, including haemolysis and other reactions, compared to recipients of ABO-identical products. The immune complexes that form in a mismatched transfusion have been demonstrated to stimulate pyrogenic cytokine release in vitro. Comparing ABO identical vs. ABO mismatched PLT transfusions, we found no significant difference in the ABO compatibilities between the PLT doses implicated in causing febrile non-haemolytic transfusion reactions (FNHTR) in 162 recipients and both the baseline PLT donor/recipient ABO compatibility (P = 0·67) or the PLTs issued in the 30 days preceding the FNHTR (P = 0·92). ABO-mismatched PLT transfusions do not appear to be aetiological agents of FNHTR in a population routinely receiving both ABO-identical and ABO-mismatched transfusions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.