Abstract

The aim of the present study was to compare the end-tidal O(2) pressure (PETO(2)) to end-tidal CO(2) pressure (PETCO(2)) in cardiac patients during rest and during 2 states of exercise: at anaerobic threshold (AT) and at peak. The purpose was to see which metabolic state, PETO(2) or PETCO(2), best correlated with exercise limitation. Thirty-eight patients with left ventricular (LV) ejection fraction <40% underwent cardiopulmonary exercise testing (CPX). PETO(2) and PETCO(2) were measured during CPX, along with peak O(2) uptake (VO(2)), AT, slope of the increase in ventilation (VE) relative to the increase in CO(2) output (VCO(2)) (VE vs. VCO(2) slope), and the ratio of the increase in VO(2) to the increase in work rate (ΔVO(2)/ΔWR). Both PETO(2) and PETCO(2) measured at AT were best correlated with peakVO(2), AT, ΔVO(2)/ΔWR and VE vs. VCO(2) slope. PETO(2) at AT correlated with reduced peak VO(2) (r=-0.60), reduced AT (r=-0.52), reduced ΔVO(2)/ΔWR (r=-0.55) and increased VE vs. VCO(2) slope (r=0.74). PETCO(2) at AT correlated with reduced peak VO(2) (r=0.67), reduced AT (r=0.61), reduced ΔVO(2)/ΔWR (r=0.58) and increased VE vs. VCO(2) slope (r=-0.80). PETCO(2) and PETO(2) at AT correlated with peak VO(2), AT and ΔVO(2)/ΔWR, but best correlated with increased VE vs. VCO(2) slope. PETO(2) and PETCO(2) at AT can be used as a prime index of impaired cardiopulmonary function during exercise in patients with LV failure.