Abstract
The distribution of defects introduced into MgO single crystals formed by MeV ion implantation was studied and then compared to the distribution calculated by using TRIM code. First, MgO single crystals were implanted with 3.1 MeV Au ions at a dose of 2 × 10 16 cm −2. Cross-sections of the crystals examined by using transmission electron microscopy revealed an abnormal distribution of the defects, namely, that the peak defect density occurred at a deeper depth (1.7–1.9 μm) than implanted-Au distribution (0.5–1.6 μm), although the peak defect density normally occurs at a shallower depth than the peak implanted-Au concentration. The ion implanted MgO crystals were irradiated with 20 keV X-ray to examine the effect of electronic excitation on the defect distribution. The X-ray irradiation considerably reduced the defect density in the implanted layer, indicating that the abnormal defect distribution is due to the effect of electronic excitation around the energetic ion tracks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.