Abstract

We report the first direct observations of deranged microcirculatory blood flow at high altitude, using sidestream dark-field imaging. Images of the sublingual microcirculation were obtained from a group of 12 volunteers during a climbing expedition to Cho Oyu (8,201 m) in the Himalayas. Microcirculatory flow index (MFI) was calculated from the moving images of microcirculatory red blood cell flow, and comparison was made between the baseline and high altitude measurements. Peripheral oxygen saturation (SpO2) and Lake Louise scores (LLS) were recorded along with MFI. Our data demonstrate that there was a significant reduction in MFI from baseline to 4,900 m in small (less than 25 μm) and medium (26–50 μm) sized blood vessels (P = 0.025 and P = 0.046, respectively). There was no significant correlation between MFI and SpO2 or MFI and LLS. Disruption of blood flow within microcirculatory may explain persistent abnormal oxygen flux to tissues following the normalisation of systemic oxygen delivery that accompanies acclimatisation to high altitude.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.