Abstract

Heat stress exposure limits based on wet-bulb globe temperature (WBGT) were designed to limit exposures to those that could be sustained for an 8-h day using limited data from Lind in the 1960s. In general, Sustainable exposures are heat stress levels at which thermal equilibrium can be achieved, and Unsustainable exposures occur when there is a steady increase in core temperature. This paper addresses the ability of the ACGIH® Threshold Limit Value (TLV®) to differentiate between Sustainable and Unsustainable heat exposures, to propose alternative occupational exposure limits, and ask whether an adjustment for body surface area improves the exposure decision. Two progressive heat stress studies provided data on 176 trials with 352 pairs of Sustainable and Unsustainable exposures over a range of relative humidities and metabolic rates using 29 participants wearing woven cotton clothing. To assess the discrimination ability of the TLV, the exposure metric was the difference between the observed WBGT and the TLV adjusted for metabolic rate. Conditional logistic regression models and receiver operating characteristic curves (ROC) along with ROC's area under the curve (AUC) were used. Four alternative models for an occupational exposure limit were also developed and compared to the TLV. For the TLV, the odds ratio (OR) for Unsustainable was 2.5 per 1°C-WBGT [confidence interval (CI) 2.12-2.88]. The AUC for the TLV was 0.85 (CI 0.81-0.89). For the alternative models, the ORs were also about 2.5/°C-WBGT, with AUCs between 0.84 and 0.88, which were significantly different from the TLV's AUC but have little practical difference. This study (1) confirmed that the TLV is appropriate for heat stress screening; (2) demonstrated the TLV's discrimination accuracy with an ROC AUC of 0.85; and (3) established the OR of 2.5/°C-WBGT for unsustainable exposures. The TLV has high sensitivity, but its specificity is very low, which is protective. There were no important improvements with alternative exposure limits, and there was weak evidence to support metabolic rate normalized to body surface area. In sum, the TLV is protective with an appropriate margin of safety for relatively constant occupational exposures to heat stress.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.