Abstract

BackgroundThe surgical treatment of posterolateral tibial plateau fractures involves a challenging and diverse set of considerations, one of which is the lack of proper and satisfactory internal fixations to purchase posterolateral fragments. Evaluating the configuration of internal fixations is often overlooked, despite it being important to outcomes of fracture fixation. This study aimed to (I) propose a new digital methodology of internal fixation evaluation that based on actual fracture cases and (II) evaluate the fixation effectiveness of four commercially available proximal tibial lateral plate-screw constructs for posterolateral fragments.MethodsTibial plateau fractures involving the posterolateral column were retrospectively reviewed. The reconstructed three-dimensional (3D) fracture models were virtually reduced, and targeted internal fixations were modeled digitally in specialized software. Four implants from three manufacturers (DePuy Synthes, Westchester, NY, USA; Zimmer, Warsaw, IN, USA; and Biomet, Warsaw, IN, USA) were placed on each fracture in an optimal position to simulate surgical fixation and quantitatively evaluate fixation effectiveness. The fragment was considered to be “captured” if it was purchased by at least two screws. The 3D fracture maps and heat maps were created by graphically superimposing all uncaptured fracture fragments onto a tibia template.ResultsThis study included 144 posterolateral tibial plateau fractures. When not using screws in a variable angle (VA) manner, the fixation effectiveness for posterolateral fragments was 58.3% for the DePuy Synthes locking compression plates (LCP), 47.9% for the DePuy Synthes VA-LCP, 50.7% for the Zimmer plate, and 43.8% for the Biomet plate. In contrast, the capturing rates boosted to 76.4% and 71.5% when utilizing VA screws in the DePuy Synthes VA-LCP and the Biomet plate. The high-frequency uncaptured areas tended to concentrate on the rim of the posterolateral wall and were mainly distributed in the posterior 1/2 to 3/4 of the parallel position of the fibula head.ConclusionsThe proposed new digital methodology was demonstrated feasible and may improve the quantitative evaluation of the implants and optimize the design of implants. The commercially available proximal tibial lateral plate-screw constructs were insufficient in capturing posterolateral fragments, and design-improved or additional implants may be necessitated.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call