Abstract
To evaluate the potential of a saline solution flush after the contrast material bolus in abdominal multidetector row CT (MDCT) in contrast material dose and cost reduction. Abdominal MDCT was performed in 78 patients who were assigned randomly to 2 groups receiving 120 mL nonionic contrast material (300 mgI/mL) alone or 100 mL of the same contrast material pushed with 40 mL of saline solution. Mean attenuation values for both groups were measured in the liver, the spleen, the pancreas, the portal vein, the inferior vena cava, and the abdominal aorta. Cost analyses were performed for both groups. There was no significant difference in parenchymal and vascular enhancement between both groups. The difference of the enhancement was 2 HU for the liver (P = 0.11), 2 HU for the spleen (P = 0.44), 3 HU for the pancreas (P = 0.38), 9 HU for the portal vein (P = 0.11), 3 HU for the inferior vena cava (P = 0.55), and 10 HU for the aorta (P = 0.06). Taking the costs of contrast material, saline solution, and disposal material into account, 7.30 dollars was saved by the patient using a saline solution flush. Using a saline flush after the contrast material bolus in abdominal MDCT allows an iodine dose reduction of approximately 6 g, or 17%, without impairing mean parenchymal and vascular enhancement and a cost reduction of 7.30 dollars per patient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.