Abstract

Background: Abbreviated breast MRI (AB-MR) achieves a higher cancer detection rate (CDR) versus digital breast tomosynthesis when applied for baseline (i.e. first-round) supplemental screening in individuals with dense breasts. Limited literature has evaluated subsequent (i.e., sequential) AB-MR screening rounds. Objectives: This study aimed to compare outcomes between baseline and subsequent rounds of screening AB-MR in individuals with dense breasts at otherwise average risk of breast cancer. Methods: This retrospective study included patients with dense breasts and at otherwise average breast-cancer risk who underwent AB-MR for supplemental screening between December 20, 2016 and May 10, 2023. Clinical interpretations and results of recommended biopsies for AB-MR examinations were extracted from the EMR. Baseline and subsequent-round AB-MR examinations were compared. Results: The final sample included 2585 AB-MR examinations (2007 baseline, 578 subsequent-round) performed for supplemental screening in 2007 women (mean age, 57.1 years) with dense breasts. Among baseline examinations, 1658 (82.6%) were assessed as BI-RADS category 1 or 2, 171 (8.5%) as category 3, and 178 (8.9%) as category 4 or 5. Among subsequent-round examinations, 533 (92.2%) were assessed as BI-RADS category 1 or 2, 20 (3.5%) as category 3, and 25 (4.3%) as category 4 or 5 (p<.001). Abnormal interpretation rate (AIR) was 17.4% (349/2007) among baseline examinations, versus 7.8% (45/578) among subsequent-round examinations (p<.001). Among baseline examinations, PPV2 was 21.3% (38/178), PPV3 was 26.6% (38/143), and CDR was 18.9 per 1000 (38/2007). Among subsequent-round examinations PPV2 was 28.0% (7/25) (p=.45), PPV3 was 29.2% (7/24) (p=.81), and CDR was 12.1 per 1000 (7/578) (p=.37). All 45 cancers diagnosed by baseline or subsequent-round AB-MR were stage 0 or 1. Seven cancers diagnosed by subsequent-round AB-MR had a mean interval since prior AB-MR of 872 days, size of 0.3-1.2 cm, and node-negative status at surgical axillary evaluation. Conclusion: Subsequent rounds of AB-MR screening in individuals with dense breasts had lower AIR compared to baseline examinations while maintaining high CDR. All cancers detected by subsequent-round examinations were early-stage node-negative cancers. Clinical Impact: The findings support sequential AB-MR for supplemental screening in individuals with dense breasts. Further investigations are warranted to optimize the screening interval.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call