Abstract

Ignition tests of overloaded electric wire were carried out in microgravity provided by airplane parabolic flight. Polyethylene insulated NiCr core wire (inner core diameter 0.5 and outer diameter 0.8 mm) was used as a test sample. The results showed that the ignition limit in terms of supplied electric power dramatically decreased with increase in microgravity time. It was suggested that the total electric energy supplied to the wire gave the primary criteria for ignition, which was consistent with experimental findings. Further, the importance of conductive heat loss to the surroundings was pointed out for very low electric current condition according to the simple one-dimensional numerical calculation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.