Abstract

The design and experimental results of a W-band gyrotron operating at the third cyclotron harmonic are presented. The gyrotron is designed to operate at the TE61 mode, which is significantly distinct from competing modes. An iris cavity is employed for the purpose of trapping the third harmonic mode more effectively and lowering its start current. In the experiment, the gyrotron is drived by a triode magnetron injection gun (MIG) which can produce a 45 kV, 3 A electron beam. When maximum axial magnetic field is 1.22 T, a single mode third harmonic gyrotron radiation is observed with the frequency of 94.86 GHz. The maximum output power is 5.5 kW, corresponding to an efficiency of 4%. Another third harmonic mode TE02 is also detected at 88.8 GHz, with maximum output power of 1.5 kW.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.