Abstract

This article proposes a fast and robust open-circuit fault diagnosis method without additional sensors for cascaded H-bridge multilevel converters (CHBMCs). The method is based on the error between the actual input-side voltage and the estimated one, with one detection threshold and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2n$ </tex-math></inline-formula> comparators in <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$n$ </tex-math></inline-formula> cascaded H-bridges. Benefitted from the simple design of the fault location, spike elimination, and parameter estimation, with the lower implementation burden, the single and multiple faults in arbitrary positions are accurately identified within a fundamental cycle, and the diagnostic robustness is guaranteed under different transient changes. In view of the low complexity, the proposed scheme can be easily applied to the CHBMCs with arbitrary modules. The experimental results from a CHBMC prototype verify the effectiveness of the proposed method under different operating conditions and fault scenarios.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.