Abstract

To generate virtual models using different hinge locations and to investigate the advantages of a temporal hinge to a superior in LASIK. The study design was cross sectional. An image processing software was used to construct virtual LASIK models of 56 slit lamp photos of eyes. For a given hinge location and width, the largest flap diameter and maximum treatable stromal bed area were calculated, comparing temporal hinge to superior. Temporal hinge allowed a greater flap diameter than superior and thus a greater treatment zone area for a given hinge width. A temporal hinge allowed a greater hinge width than a superior hinge for a given treatment zone area. We provide a rational basis for a mechanically stable temporal hinge. Moreover, we provide a method to pre-operative model flap size and hinge location, using a slit lamp camera and an image editing software.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.