The second harmonic current compensator (SHCC) can be added into the single-phase converters for compensating the second harmonic current (SHC) and thus removing the undesired electrolytic capacitor. In this paper, a virtual impedance, which is in the form of a capacitor and a resistor connected in parallel, is introduced to be in parallel at the bus-side port of the SHCC for effectively compensating the SHC while guaranteeing the system stability. This virtual parallel impedance is realized by feeding forward the bus-side port voltage of the SHCC, and thus the SHCC can be modular designed. The closed-loop parameter design of the SHCC is also presented. A 3.3-kW prototype of a two-stage single-phase power factor correction converter is built and tested in the laboratory, and the experimental results verify the effectiveness and feasibility of the proposed control method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.