Abstract

Here I describe a very simple, very effective, and very inexpensive method of dichoptic stimulus presentation, designed for use in a head-only MRI scanner with a standard back-projection system. The method can also be used outside of the scanner. Images are presented separately and simultaneously to the two eyes, without the use of colored lenses, with no constraints on stimulus properties (other than size: stimuli must be less than half of the width of the viewing screen), no degradation in luminance reaching the eye, and zero crosstalk between the two eyes. Simultaneous infrared eye tracking and/or pupilometry can also be performed. Components include a two-part cardboard divider (one part in the bore of the magnet, and one in the head coil) and prism lenses (readily obtainable from the local eyeglass shop) cut to fit scanner-compatible eyeglass frames. The total cost (in 2007) was approximately US$ 300.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.