Abstract

A number of rubbery and glassy membranes have been prepared and evaluated in vapor permeation experiments for separation of aromatic/aliphatic mixtures, using 5/95 (wt:wt) toluene/methylcyclohexane (MCH) as a model solution. Candidate membranes that met the required toluene/MCH selectivity of ≥ 10 were identified. The stability of the candidate membranes was tested by cycling the experiment between higher toluene concentrations and the original 5 wt% level. The best membrane produced has a toluene permeance of 280 gpu and a toluene/MCH selectivity of 13 when tested with a vapor feed of the model mixture at its boiling point and at atmospheric pressure. When a series of related membrane materials are compared, there is a sharp trade-off between membrane permeance and membrane selectivity. A process design study based on the experimental results was conducted. The best preliminary membrane design uses 45% of the energy of a conventional distillation process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.