Abstract

A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of Varde- nafil and its related impurities in both bulk drugs and Pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a simple gradient pro- gramme and quantitation was by ultraviolet detection at 210 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 0.25 ml?min–1. Buffer consisted of 20 mM Ammonium bi carbonate, pH adjusted to 5.0 by using ortho Phosphoric acid. In the developed UPLC method the resolution (Rs) between vardenafil and its four potential impurities was found to be grater than 2.0.Regrreation analysis showed an r value (correlation coefficient) grater than 0.999 for vardenafil and its four impurities. This method was capable to detect all four impurities of vardenafil at a level of 0.25 μg.mL–1 with respect to test concentration of 500 μg?ml–1 for a 2 μl injection volume. The inter and intra day precision values for all four impurities and for vardenafil was found to be with in 2.0% RSD. The method showed good and consistent recoveries for vardenafil in bulk drugs (98.8% - 100.9%), pharmaceutical dosage forms (100.5% - 101.5%) and its all four impurities (99.8% - 102.5%).The test solutions was found to stable in acetonitrile for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation. Considerable degradation was found to occur in peroxide hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.9%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.

Highlights

  • Vardenafil HCl, 2-[2-ethoxy-5(4-ethyl-piperazine-1-sulphonyl)-phenyl]-5-methyl-7-propyl-3H-imidazo [5,1-f] [1,2,3] triazin-4-one hydrochloride (Figure 1) is used to treat erectile dysfunction

  • A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of Vardenafil and its related impurities in both bulk drugs and Pharmaceutical dosage forms

  • Effective chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a simple gradient programme and quantitation was by ultraviolet detection at 210 nm

Read more

Summary

Introduction

Vardenafil HCl, 2-[2-ethoxy-5(4-ethyl-piperazine-1-sulphonyl)-phenyl]-5-methyl-7-propyl-3H-imidazo [5,1-f] [1,2,3] triazin-4-one hydrochloride (Figure 1) is used to treat erectile dysfunction. Efficacy of PDE-5 inhibitors as a treatment for ED, their draw backs are notable. Adverse effects such as head ache, facial flushing, dyspepsia, visual disturbances and muscle aches have been reported [3]. A few HPLC methods determination of vardenafil in bulk drug and biological samples were reported in the literature [610]. An attempt has been made to develop an accurate, rapid, specific and reproducible method for determination of vardenafil and all four impurities in bulk drug samples and in pharmaceutical dosage forms along with method validation as per ICH norms [11,12,13]. The stability tests were performed on both drug substances and drug products as per ICH norms [14,15,16]

Experimental
Chromatographic Conditions
Preparation of Solutions
Equipment
Preparation of Sample Solutions
Specificity
Analytical Method Validation
Sensitivity
Linearity and Range
Accuracy
Robustness
Solution Stability and Mobile Phase Stability
Method Developed and Optimization
Results of Forced Degradation Studies
Precision
Limit of Detection and Limit of Quantification
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.