Abstract

A simple, rapid, accurate and reproducible reverse-phase HPLC method has been developed for the identification and quantification of two alkaloids ephedrine and cryptolepine in different extracts of Sida species using photodiode array detection. Baseline separation of the two alkaloids was achieved on a Waters RP-18 X-terra column (250 × 4.6 mm, 5 µm) using a solvent system consisting of a mixture of water containing 0.1% Trifluoroacetic acid (TFA) and acetonitrile in a gradient elution mode with detection at 210 and 280 nm for ephedrine and cryptolepine, respectively. The calibration curves were linear in a concentration range of 10-250 µg/mL for both the alkaloids with correlation coefficient values >0.99. The limits of detection and quantification for ephedrine and cryptolepine were 5 and 10 µg/mL and 2.5 and 5 µg/mL, respectively. Relative standard deviation values for intra-day and inter-day precision were 1.22 and 1.04% for ephedrine and 1.71 and 2.06% for cryptolepine, respectively. Analytical recovery ranged from 92.46 to 103.95%. The developed HPLC method was applied to identify and quantify ephedrine and cryptolepine in different extracts of Sida species.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call