Abstract

A high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed and validated for the quantitation of dexibuprofen in dexibuprofen tablets using ovomucoid chiral stationary phase (Ultron ES-OVM). The mobile phasewas composed of 0.025 M potassium phosphate dibasic (pH 4.5)-methanol-ethanol (85:10:5 v/v/v). The method was validated for specificity, linearity, range, accuracy, precision and robustness. The method was enantiomerspecific for the determination of dexibuprofen [S-(+)-isomer ibuprofen] in the presence of R-(-)-isomer ibuprofen in bulk drug, pharmaceutical dosage form and under stress degradation. The method was linear over the range 15-35 mg/mL with r² = 0.9995; accuracy and precision were acceptable with %RSD < 2.0%. The method was found to be specific, precise, accurate, robust and stability-indicating, and can be successfully applied for the routine analysis of dexibuprofen in bulk drug and pharmaceutical dosage form.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.