Abstract
BackgroundOptic nerve sheath diameter (ONSD) measurement using ultrasound has been proposed as a rapid, non-invasive, point of care technique to estimate intra-cranial pressure (ICP). Ultrasonic measurement of the optic nerve sheath can be quite challenging and there is limited literature surrounding learning curves for this technique. We attempted to develop a method to estimate the reliability learning curve for ONSD measurement utilizing a unique definition of reliability: a plateau in within-subject variability with unchanged between-subject variability.MethodsAs part of a previously published study, a single operator measured the ONSD in 120 healthy volunteers over a 6-month period. Utilizing the assumption that the four measurements made on each subject during this study should be equal, the relationship of within-subject variance was described using a quadratic-plateau model as assessed by segmental polynomial (knot) regression.ResultsSegmental polynomial (knot) regression revealed a plateau in within-subject variance after the 21st subject. However, there was no difference in overall mean values [3.69 vs 3.68 mm (p = 0.884)] or between-subject variance [14.49 vs 11.92 (p = 0.54)] above or below this cutoff.ConclusionsThis study suggests a significant finite learning curve associated with ONSD measurements. It also offers a unique method of calculating the learning curve associated with ONSD measurement.
Highlights
Optic nerve sheath diameter (ONSD) measurement using ultrasound has been proposed as a rapid, non-invasive, point of care technique to estimate intra-cranial pressure (ICP) [3]
Segmental polynomial regression revealed a plateau in within-subject variance, var(I), at subject index (I) 21 (Fig. 1)
Based on the segmental polynomial regression and the plateau of within-subject variance at subject 21 we utilized this as the cut-off for defining early vs late measurements
Summary
Optic nerve sheath diameter (ONSD) measurement using ultrasound has been proposed as a rapid, non-invasive, point of care technique to estimate intra-cranial pressure (ICP). Ultrasonic measurement of the optic nerve sheath can be quite challenging and there is limited literature surrounding learning curves for this technique. Optic nerve sheath diameter (ONSD) measurement using ultrasound has been proposed as a rapid, non-invasive, point of care technique to estimate ICP [3]. This has been suggested as a screening tool for, or even an alternative to, invasive ICP. The literature surrounding learning curves for point of care ultrasound in general is limited [10] and even more so for the specific technique of ONSD measurement [11]. We attempt to employ a unique statistical method for estimating the potential learning curve for ONSD measurement
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.