Abstract

The multi-baseline synthetic aperture radar (SAR) tomography (TomoSAR) system is employed in such applications as disaster remote sensing, urban 3-D reconstruction, and forest carbon storage estimation. This is because of its 3-D imaging capability in a single-pass platform. However, a high 3-D resolution of TomoSAR is based on the premise that the channel imbalance and antenna phase center (APC) position are precisely known. If this is not the case, the 3-D resolution performance will be seriously degraded. In this paper, a unified algorithm for channel imbalance and APC position calibration of a single-pass multi-baseline TomoSAR system is proposed. Based on the maximum likelihood method, as well as the least squares and the damped Newton method, we can calibrate the channel imbalance and APC position. The algorithm is suitable for near-field conditions, and no phase unwrapping operation is required. The effectiveness of the proposed algorithm has been verified by simulation and experimental results.

Highlights

  • In recent years, synthetic aperture radar (SAR) tomography (TomoSAR) has become a popular research topic due to its 3-D imaging capability [1,2,3,4,5,6]

  • We propose a unified algorithm for the channel imbalance and antenna phase center (APC) position calibration of a single-pass multi-baseline TomoSAR system, which can calibrate channel imbalance but can calibrate the APC position

  • Features of this algorithm are as follows: (1) the channel imbalance and APC position can be calibrated individually rather than confusing the phase error caused by the APC position error with the phase error of the channel itself; (2) the Fresnel approximation is used in the calibration signal model, which heightens the accuracy of the calibration signal model; and (3) there is no need for phase unwrapping

Read more

Summary

Introduction

Synthetic aperture radar (SAR) tomography (TomoSAR) has become a popular research topic due to its 3-D imaging capability [1,2,3,4,5,6]. If we hope to obtain a super-resolution performance in the height direction, high requirements for the channel imbalance ( known as amplitude and phase inconsistency) and APC position calibration are required in a single-pass multi-baseline TomoSAR system. We propose a unified algorithm for the channel imbalance and APC position calibration of a single-pass multi-baseline TomoSAR system, which can calibrate channel imbalance but can calibrate the APC position Features of this algorithm are as follows: (1) the channel imbalance and APC position can be calibrated individually rather than confusing the phase error caused by the APC position error with the phase error of the channel itself; (2) the Fresnel approximation is used in the calibration signal model, which heightens the accuracy of the calibration signal model; and (3) there is no need for phase unwrapping.

A Signal Model
Step 1
Step 2
Validation with Simulation Data
Experimental Results
B Building
Conclusions

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.