Abstract

This paper describes a two-step damage detection and health monitoring approach that was developed for large and complex structures with a limited number of measurements. The first step identifies a general area of structural damage using the optimal model update method and a hybrid model reduction/eigenvector expansion technique. The second step locates a specific damaged structural component using a design sensitivity technique based on a priori information from the first damage detection step. Performance of the proposed damage detection approach was demonstrated with testing and analysis ofa ten-bay hexagonal truss structure. Procedures developed for the damage detection are also directly applicable to test/dynamic math model correlation when the number of measurements is limited.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.