Abstract

A two-stage minibioreactor system was successfully developed for continuous toxicity monitoring. This system consists of two minibioreactors in series. Recombinant Escherichia coli DPD2794 containing a RecA::luxCDABE fusion as a model strain was utilized to monitor environmental insults to DNA, with mitomycin C as a model toxicant. Pulse type exposures were used to evaluate the system’s reproducibility and reliability. Step inputs of mitomycin C have been adopted to show the system’s stability. The system’s ability to monitor the possible upsets or accidental discharges of toxic chemicals was also evaluated with these step insults. All the data demonstrated that this two-stage minibioreactor system using recombinant bacteria containing stress promoters fused with lux genes is quite appropriate for continuous toxicity monitoring. Long-term operation and minimized media-usage have been investigated. Thus application to many different areas, including an early warning system of wastewater biotreatment plant upsets and the monitoring and tracking of accidental spills, discharges or failures in plant operation are plausible.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.