Abstract

This paper presents a two-dimensional analysis for the efficiency of an elliptic fin under the dry, partially wet and fully wet conditions of a range of value for axis ratios, Biot numbers, and air humidifies. It is shown that the fin efficiencies increase as the axis ratio Ar is increased. For a given axis ratio Ar, the fin efficiency decreases as the fin height l ∗ or Biot number is increased. The conventional 1-D sector method overestimates the fin efficiency resulting in increasing error as the axis ratio Ar is increased. In addition, using experimentally determined heat transfer coefficients, it is found that both the fully dry and wet elliptic fin efficiencies are up to 4–8% greater than the corresponding circular fin efficiencies having the same perimeter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.